Adsorbent bed loading is the placement of the support screen, graded inert layers, adsorbent and hold down layer in a dryer or adsorber vessel, and it determines how evenly gas flows through the bed for the whole life of the charge. A bed with the correct adsorbent and regeneration settings can still miss its outlet dew point if it is loaded poorly. Channelling, crushed beads and high pressure drop are the typical results, and most of them can only be corrected by unloading the vessel.
The same method applies to molecular sieve for gas drying, activated alumina in compressed air dryers and activated carbon in purification beds.
Layers of a Loaded Adsorber Vessel
The vessel is loaded in six parts, from the bottom up. Omitting any one of them usually appears later in operation as dust in the product line or early breakthrough.
Typical layout of a downflow adsorber vessel after loading
| Layer | Function | Common practice |
| Support grating and wire mesh | Carries the bed and retains the media above the outlet | Mesh opening around 1 mm, with allowance for thermal movement of the vessel |
| Graded inert layers below the bed | Distribute the flow and prevent the adsorbent from settling into the screen | At least 150 mm in total, often two layers of 75 mm or more, such as 13 mm balls under 6 mm balls |
| Adsorbent bed | Removes water or the target contaminant | Bed height as set by the vessel designer |
| Floating screen | Separates the adsorbent from the layer above, so each can be unloaded without mixing | Placed on the levelled bed surface |
| Hold down layer | Protects the top of the bed | At least 100 mm of 13 mm balls, or about 150 mm where the inlet has no distributor |
| Inlet distributor and plenum | Prevents the incoming gas from striking one point of the bed | Open space above the hold down layer, with a distributor on the inlet nozzle |
These values reflect common practice for molecular sieve and activated alumina dryers, and the vessel designer or licensor sets the final heights for each unit. In vessels above about 3 m in diameter, each inert layer is normally increased to around 100 mm.
Grading of the Inert Support Layers
When small beads rest directly on much larger balls, they migrate into the voids between them. This effect, known as nesting, fills the open space and raises the pressure drop across the vessel. The inert layers are therefore graded so that the ball diameter roughly halves from one layer to the next, working upwards, until the layer directly beneath the adsorbent is about twice the bead diameter. At this ratio the voids are too small for the layer above to pass into.
Grading is equally important during regeneration. The regeneration gas flow can be as low as about 5% of the feed flow, and at that rate it follows the path of least resistance. A well graded support distributes it across the full diameter, which matters because any part of the bed left incompletely regenerated can raise the outlet dew point in the following cycle.
Function of the Hold Down Layer
The hold down layer provides weight rather than filtration, so its size is less critical than that of the lower layers. It prevents the beads from lifting and abrading against each other during pressurisation and depressurisation, which would otherwise form dunes on the bed surface, reduce the effective bed depth and generate dust. The layer also shields the adsorbent from the incoming gas stream and helps spread it across the bed.
Loading Procedure
Loading is preferably carried out in dry weather, with containers kept closed until use, as most adsorbents begin to take up moisture as soon as they are exposed to air.
- Inspect and mark the vessel. Confirm that the vessel is clean and dry, the support grating is sound and the seal between the screen and the vessel wall is intact, then mark the planned top of each layer on the inside wall.
- Fit the bottom screen. Lay the mesh over the full area of the grating, leaving no gap through which media can pass.
- Load the inert layers, largest first. Level each size and check its height before the next one is added, and fill any unloading nozzle with support media as specified.
- Load the adsorbent in even lifts. Move the loading sock continuously so that no heaps form, and level each lift. A free fall of about 7 m from the sock outlet to the bed surface is the usual limit before bead breakage increases.
- Place the floating screen and hold down layer. Lay the screen flat and bring the top layer to its full height.
- Close the vessel and regenerate. Remove all packaging, close the manholes and regenerate the bed before it goes on line.
The graded support layers and the hold down layer are made from inert ceramic balls or high purity alumina balls. The right choice depends on the operating temperature, the process stream and the vessel design, so Medaad’s engineering team reviews the operating conditions of each unit with the customer and selects the support media accordingly.
Nitrogen PSA generators filled with carbon molecular sieve follow a different method. The bed is packed by dense loading with a snowstorm filler and held in place with adsorbent compression pads instead of a loose top layer.
Adsorbents and Support Media From Medaad
Medaad, by SorbiTech, supplies molecular sieve, activated alumina and activated carbon to customers worldwide, together with the inert media for the same vessel and technical documentation for every batch. The same team also checks the planned layer heights against the vessel drawing and supervises loading and commissioning.
Contact Medaad about your adsorbent bed loading requirement.